Fittings and adapters
Metering Line Assembly with Headers and Instruments
- Bounding box
- 2460.2 × 630.0 × 3190.2 mm
- Engine
- Precision B-rep
- Parameters
- 27
- Published
- October 1, 2026
Download
Free to download and use. See the terms.
The prompt
Design a metering line assembly for an oil quantity and quality measurement system. The assembly must consist of an inlet header, an outlet header, and two metering lines. Both headers must be equipped with two Metran pressure transmitters (one with a display, one without) and two Elemer temperature transmitters (one with a display, one without). The metering lines must be fitted with a flanged Coriolis mass flow meter, a temperature transmitter, and a pressure transmitter. Pressure transmitters are to be connected via a boss, and temperature transmitters via a flange. The header diameter is 400 mm, and the metering line diameter is 250 mm. The header must start with a flange and terminate with an elliptical end cap.
Parameters
| Name | Value | Range |
|---|---|---|
| Header Pipe OD | 400 mm | 300 – 600 |
| Header Wall Thickness | 10 mm | 5 – 20 |
| Header Pipe Length | 3000 mm | 2000 – 5000 |
| Header Flange OD | 560 mm | 500 – 700 |
| Header Flange Thickness | 40 mm | 20 – 60 |
| Header End Cap Height | 150 mm | 100 – 250 |
| Metering Pipe OD | 250 mm | 150 – 350 |
| Metering Wall Thickness | 8 mm | 5 – 15 |
| Metering Line Length | 1500 mm | 1000 – 2500 |
| Lower Metering Line Height Above Flange | 500 mm | 200 – 1000 |
| Upper Metering Line Height Above Flange | 1900 mm | 1200 – 2800 |
| Coriolis Meter Body OD | 380 mm | 200 – 500 |
| Coriolis Meter Body Length | 800 mm | 400 – 1200 |
| Pressure Boss OD | 60 mm | 30 – 100 |
| Pressure Boss Length | 80 mm | 40 – 120 |
| Pressure Transmitter Body OD | 80 mm | 50 – 120 |
| Pressure Transmitter Body Length | 120 mm | 60 – 200 |
| Temperature Nozzle OD | 80 mm | 40 – 120 |
| Temperature Nozzle Length | 100 mm | 60 – 160 |
| Temperature Flange OD | 120 mm | 80 – 160 |
| Temperature Flange Thickness | 20 mm | 10 – 30 |
| Temperature Transmitter Body OD | 60 mm | 40 – 100 |
| Temperature Transmitter Body Length | 100 mm | 60 – 160 |
| Display Width | 50 mm | 20 – 80 |
| Display Height | 40 mm | 20 – 60 |
| Display Depth | 10 mm | 5 – 20 |
| Metering Instrument Offset from Center | 250 mm | 100 – 600 |
Every value above is a live dimension. Open a model like this in the editor and each one becomes a slider you can drag before exporting.
More models
Browse the full gallery →SM1 to RMS Thread Adapter
thorlabs SM1A3 adapter has external SM1 (1.035"-40) threading and internal RMS (0.800"-36) threading.
Shouldered Spacer 20/26 x 15
Create a mechanical shouldered spacer from scratch. Main body: 20 mm outer diameter and 12 mm height. Add a concentric flange at the bottom: 26 mm outer diameter and 3 mm thickness
Cylindrical D-Shaft Flange
Create a cylindrical flange with a base diameter of 40 mm and a total height of 15 mm. Feature an 8 mm central D-shaft bore through the entire height. On the bottom 4 mm thick flan
Radial Lip Seal 75×100
make a seal that has inner diameter equal of 75mm outer diameter of 100 mm and it should rest on the inner diameter of a flange like part
Micrometer Expansion Tool
Turn Screw │ ▼ Micrometer Screw │ ▼ Tapered Cone Moves │ ▼ Four Jaws Expand Evenly
DN-100 Pipe Spool with Flanges
A steel tube with two DN-100 flanges in each end