858.12381.81396.0
Loading the interactive model…
Interactive 3D model of MAF25C MR-624 Direct Drive Blower + 250x370 to DN500 Flanged Adapter

Fittings and adapters

MAF25C MR-624 Direct Drive Blower + 250x370 to DN500 Flanged Adapter

1 views
Bounding box
2381.8 × 858.1 × 1396.0 mm
Engine
Precision B-rep
Parameters
31
Published
November 5, 2026

Download

Free to download and use. See the terms.

The prompt

Upgrade previously shape-corrected Marvel Air Flow MAF25C 30HP direct-drive blower assembly by adding an IN-LINE HOLLOW stainless rectangular-to-round transition to existing left-facing horizontal 250x370mm outlet. Match original 350x470mm 14xØ14 rectangular bolt pattern. Provide a 650mm gradual 250x370 -> DN500 transition expanding towards -X with 4mm wall, DN500 clear bore, 150mm circular straight pipe end, and provisional 620OD/580PCD 16xØ14 circular duct flange. Keep all existing fan geometry, outlet damper, inlet, impeller, motor and foundation in correct original positions. This CAD is preliminary only; duct flange supplier and pressure losses to be verified.

Parameters

NameValueRange
Base width in elevation690 mm680 – 730
Base length inlet-to-motor850 mm820 – 900
Base channel height100 mm95 – 120
Base channel web/flange50 mm45 – 65
Fan shaft X datum0 mm-50 – 50
Motor/impeller shaft elevation630 mm620 – 650
Volute axial thickness (estimated)335 mm315 – 375
Volute wall thickness (estimated)6 mm4 – 8
Inlet flange clear bore355 mm345 – 365
Inlet flange outside diameter455 mm450 – 465
Inlet flange PCD410 mm400 – 420
Connection bolt-hole diameter14 mm13 – 16
Impeller diameter from GA model designation570 mm550 – 610
CCW impeller blade count (estimated)108 – 12
Outlet clear Y width250 mm240 – 270
Outlet clear Z height370 mm350 – 390
Outlet flange outer width350 mm340 – 370
Outlet flange outer height470 mm450 – 490
Top of horizontal outlet opening1271 mm1260 – 1285
Outlet damper axial projection375 mm360 – 410
30 HP motor frame body OD (estimated)260 mm230 – 300
30 HP motor body length (estimated)315 mm290 – 360
Direct drive motor front y datum95 mm65 – 125
Motor mounting plate gauge12 mm10 – 16
250x370 to DN500 expansion length650 mm500 – 1100
Round outlet clear bore DN500500 mm450 – 550
DN500 straight duct end length150 mm100 – 300
DN500 duct flange outer diameter (provisional)620 mm590 – 670
DN500 flange bolt PCD (provisional)580 mm550 – 620
DN500 air duct flange bolt count1612 – 20
Transition sheet wall thickness4 mm3 – 6

Every value above is a live dimension. Open a model like this in the editor and each one becomes a slider you can drag before exporting.