3D preview of Nuclear Medicine Center Functional Floor Plan (Parametric Wall Model)
Loading the interactive model…
Interactive 3D model of Nuclear Medicine Center Functional Floor Plan (Parametric Wall Model)

Mechanical parts

Nuclear Medicine Center Functional Floor Plan (Parametric Wall Model)

5 views
Bounding box
66000.0 × 36400.0 × 4600.0 mm
Engine
Precision B-rep
Parameters
33
Published
August 21, 2026

Download

Free to download and use. See the terms.

The prompt

Create a **2D architectural floor plan in DWG format** for a new **Nuclear Medicine Center**. This is a **generic conceptual functional layout**, NOT a construction-ready project. Do not calculate radiation shielding, structural, MEP or regulatory requirements. Use metric units and create editable 2D CAD geometry with walls, doors, corridors, room labels and generic equipment footprints. ### REQUIRED AREAS **PUBLIC** * Main entrance * Reception * Patient waiting area * Patient/companion bathroom **MEDICAL** * Nuclear Medicine Physician Office * Staff bathroom **GAMMA CAMERA** * Gamma Camera Room * Gamma Camera Control/Console Room * Patient preparation area * Patient bathroom **PET/CT** * PET/CT Room * PET/CT Control/Console Room * Patient preparation/injection area * Patient uptake/waiting area * Patient bathroom **RADIOPHARMACY** * Tc-99m / I-131 Radiopharmacy * F-18 / Ga-68 PET Radiopharmacy * **PET Radiopharmacy Quality Control Room** * Radioactive Material Receiving Area * Radioactive Material Decay/Waste Area * Storage/Support Area **I-131 THERAPY** * I-131 Patient Room 1 + private bathroom * I-131 Patient Room 2 + private bathroom * Controlled corridor/access **SUPPORT** * General storage * Cleaning/janitorial room * Staff/support area * Corridors and circulation ### LAYOUT LOGIC Organize the center into functional zones. Public flow: **Entrance → Reception → Waiting → Clinical Areas → Exit** Gamma Camera: **Patient Preparation → Gamma Camera → Control Room** PET/CT: **Preparation/Injection → Uptake/Waiting → PET/CT → Exit** Radiopharmacy: **Radioactive Material Receiving → Radiopharmacy → Quality Control → Patient Preparation** Waste: **Clinical/Radiopharmacy Areas → Radioactive Waste → Decay Area** I-131: Create a separate controlled therapy zone with the two patient rooms. Each room must have its own private bathroom. Keep public areas separated from controlled radioactive-material areas. Place each imaging control room directly adjacent to its corresponding imaging room. Place **PET Quality Control directly adjacent to the F-18/Ga-68 PET Radiopharmacy**. Create a clear, efficient circulation system with corridors connecting all areas. Include generic Gamma Camera and PET/CT equipment footprints. Title: **GENERIC NUCLEAR MEDICINE CENTER — FUNCTIONAL FLOOR PLAN** Add: **CONCEPTUAL / REFERENCE LAYOUT — NOT FOR CONSTRUCTION**

Parameters

NameValueRange
Base Slab Thickness100 mm50 – 300
Wall Thickness200 mm100 – 400
Wall Height3000 mm2000 – 6000
Equipment Footprint Height900 mm500 – 2000
Public Waiting Length12000 mm8000 – 20000
Public Waiting Width8000 mm6000 – 15000
Clinical Office Length10000 mm6000 – 20000
Clinical Office Width8000 mm6000 – 15000
Gamma Suite Length14000 mm10000 – 25000
Gamma Suite Width10000 mm8000 – 20000
Gamma Camera Footprint Length2400 mm1500 – 4000
Gamma Camera Footprint Width1800 mm1000 – 3000
Gamma Control Room Length4000 mm2500 – 8000
Gamma Control Room Width4000 mm2500 – 8000
PET/CT Suite Length16000 mm12000 – 30000
PET/CT Suite Width12000 mm10000 – 22000
PET/CT Gantry Footprint Length2500 mm1500 – 4000
PET/CT Gantry Footprint Width2200 mm1500 – 4000
PET/CT Control Room Length5000 mm3000 – 9000
PET/CT Control Room Width4000 mm3000 – 8000
Tc-99m/I-131 Pharmacy Length8000 mm5000 – 15000
Tc-99m/I-131 Pharmacy Width6000 mm4000 – 12000
Fume Hood Footprint Length1500 mm800 – 3000
Fume Hood Footprint Width800 mm500 – 1500
Dispensing Bench Footprint Length1200 mm600 – 2500
Dispensing Bench Footprint Width600 mm400 – 1200
F-18/Ga-68 PET Pharmacy Length10000 mm7000 – 18000
F-18/Ga-68 PET Pharmacy Width8000 mm6000 – 15000
Waste/Decay Zone Length12000 mm8000 – 20000
Waste/Decay Zone Width6000 mm4000 – 12000
I-131 Ward Length15000 mm12000 – 25000
I-131 Ward Width10000 mm8000 – 18000
Main Corridor Width2400 mm1500 – 4000

Every value above is a live dimension. Open a model like this in the editor and each one becomes a slider you can drag before exporting.