Enclosures and housings
Insulated Gas Boiler Cabinet with ZOTA Boiler, Door and Flue
- Bounding box
- 660.0 × 821.3 × 1220.0 mm
- Engine
- Precision B-rep
- Parameters
- 21
- Published
- November 9, 2026
Download
Free to download and use. See the terms.
The prompt
Create a precise, editable 3D CAD model of an outdoor insulated metal gas boiler cabinet based on the uploaded reference images and technical drawing. IMPORTANT: The technical drawing defines the geometry and dimensions. The cabinet reference photo defines the exterior appearance. The uploaded ZOTA Plasma 36 S photo defines the boiler appearance. CABINET DIMENSIONS: - Height: 1220 mm. - Width: 600 mm. - Depth: 540 mm (520 mm is also indicated in the side drawing; keep depth editable and do not assume these dimensions are interchangeable). - Metal sheet thickness: 1.5 mm. - Insulation thickness: 50 mm. EXTERIOR: - Tall rectangular industrial metal enclosure. - Dark anthracite grey matte powder-coated steel. - Clean, realistic sheet-metal construction. - No KAINAR logo, no brand labels, no stickers. - No door lock. - Front access door with visible metal hinges. - The door must be a separate movable component and must be shown partially open in one assembly configuration. CRITICAL UPPER CONSTRUCTION: - The upper flue outlet area must be integrated into the left and right side walls. - Do NOT create a separate overlapping decorative cover or an additional upper overlay panel. - Do NOT create unnecessary vertical seams on the left and right sides of the upper construction. - Preserve the intended central joint only in the middle area around the flue cutout, according to the technical reference. - Do not add unnecessary rivets or fasteners to the upper section. BOILER: - Place a ZOTA Plasma 36 S boiler inside the cabinet. - Use the uploaded boiler photo as the visual reference. - Keep the boiler inside the cabinet, correctly positioned and proportioned. - Include realistic pipe connections and fittings. FLUE PIPE: - The flue must follow the side-view technical drawing. - It must rise from the boiler, make the required bend and pass through the designated opening in the cabinet side wall. - The pipe must visibly exit OUTSIDE the cabinet. - Do not route the flue behind the cabinet or into an invisible rear wall. - The flue outlet must be visible in the open-door view. MODEL REQUIREMENTS: - Build actual editable solid CAD geometry, not just a rendered image or decorative mesh. - Keep the cabinet, door, hinges, boiler and flue as separate components. - Preserve correct proportions. - Use millimeters as the modeling units. - Do not invent additional design features. - Do not change the cabinet's overall proportions. OUTPUT: Create an editable 3D model suitable for further engineering work. Provide STEP export if supported, as well as STL. Also provide front, side, rear and isometric views.
Parameters
| Name | Value | Range |
|---|---|---|
| Cabinet Height | 1220 mm | 800 – 2000 |
| Cabinet Width | 600 mm | 400 – 1200 |
| Cabinet Depth | 540 mm | 350 – 900 |
| Sheet Metal Thickness | 1.5 mm | 0.8 – 5 |
| Insulation Thickness | 50 mm | 10 – 100 |
| Door Width | 560 mm | 200 – 1100 |
| Door Height | 1120 mm | 200 – 1900 |
| Door Sheet Thickness | 1.5 mm | 0.8 – 5 |
| Door Open Angle | 30 deg | 0 – 80 |
| Hinge Length | 60 mm | 20 – 120 |
| Hinge Leaf Width | 20 mm | 8 – 50 |
| Hinge Barrel Diameter | 15 mm | 6 – 40 |
| Boiler Width | 430 mm | 150 – 560 |
| Boiler Height | 780 mm | 200 – 1150 |
| Boiler Depth | 390 mm | 150 – 520 |
| Boiler Front Clearance | 5 mm | 0 – 60 |
| Pipe Outside Diameter | 33.7 mm | 10 – 80 |
| Flue Pipe Diameter | 150 mm | 60 – 300 |
| Side Wall Flue Cut-out Dia | 160 mm | 70 – 320 |
| Flue Outlet Height | 940 mm | 500 – 1180 |
| Flue External Protrusion | 60 mm | 0 – 300 |
Every value above is a live dimension. Open a model like this in the editor and each one becomes a slider you can drag before exporting.
More models
Browse the full gallery →Cylindrical Stainless Steel Basket with Folding Handles
Design a cylindrical 304 stainless steel basket with an outer diameter of 200 mm and height of 250 mm. The basket has solid side walls with no perforations. The bottom plate contai
Immersion Cooling Enclosure
Design a sealed high-pressure dielectric immersion cooling enclosure for cylindrical battery cells. Internal cavity dimensions: 540mm length, 360mm width, 160mm height with 6mm wal
Simple BWB with Propulsion Tube
Prompt: "A simple, solid Blended Wing Body (BWB) flying wing. Dimensions: wingspan 6.5 meters, center chord 1.53 meters, root thickness 35 centimeters, tapering to 15 centimeters a
Engranaje recto 50 dientes, módulo 2
Engranaje recto de 50 dientes, diámetro exterior 104 mm, diámetro de raíz 95 mm, espesor 10 mm y ángulo de presión 20°. Crear como sólido 3D con un agujero central de 8.2 mm de diá
G+1 Party Hall Structural Shell
G+1 Party Hall – AutoCAD Design Prompt Design a G+1 RCC-framed Party Hall in AutoCAD with detailed Ground Floor Plan, First Floor Plan, and all-side elevations (front, rear, left
Default Spur Gear
La costruzione dovrà prevedere i seguenti spazi: 1. Zona Giorno (Piano Terra)-Totale:~110 mg • Ingresso / Disimpegno con guardaroba: 10 mg • Soggiorno / Area Living: 40 mq (ampio,
