3D preview of Hydraulic Wing and Flaperon Demonstrator
Loading the interactive model…
Interactive 3D model of Hydraulic Wing and Flaperon Demonstrator

Brackets and mounts

Hydraulic Wing and Flaperon Demonstrator

1 views
Bounding box
227.0 × 277 × 58.8 mm
Engine
3D Printing B-rep
Parameters
52
Published
November 19, 2026

Download

Free to download and use. See the terms.

The prompt

# Hydraulic Aircraft Wing and Flaperon CAD Model Create a detailed, parametric 3D CAD model of a small aircraft wing with a hydraulically actuated movable flaperon. Follow the supplied reference sketch. ### 1. Wing Geometry - Chord: 240 mm. - Wingspan: 120 mm. - Maximum thickness: 48 mm. - Movable rear flaperon: 60 mm chord. - Rounded leading edge, curved upper surface and relatively flat underside. - Separate movable flaperon hinged along the wingspan near the upper rear edge. - Flaperon must rotate approximately 30° downward and return to alignment. ### 2. Hydraulic System Design the mechanism around two real commercially purchased syringes: - Internal actuator: InJ/Light 60 ml syringe. - External controller: KL MED 20 ml syringe. **IMPORTANT: DO NOT MODEL THE SYRINGES AS PRINTABLE COMPONENTS.** Instead, create hollow mounting compartments and removable retaining clips. For preliminary dimensional planning, use: - 60 ml syringe: approximately 29 mm barrel diameter and 125 mm barrel length. - 20 ml syringe: approximately 21 mm barrel diameter and 103 mm barrel length. These are generic reference dimensions, NOT verified manufacturer measurements. Make all syringe dimensions adjustable through parameters, allowing corrections after physical measurement. Position the internal syringe horizontally, with its nozzle facing the leading edge and plunger facing the flaperon. Provide sufficient clearance for plunger movement. Create an external removable cradle for the 20 ml syringe, keeping its plunger accessible. ### 3. Linkage and Tubing Connect the internal syringe plunger to a flaperon-mounted control horn using a short pivoting mechanical linkage. Include suitable pivot holes, hinge supports, connecting pins and mechanical clearances. The external syringe must connect to the internal syringe through real flexible tubing. DO NOT MODEL tubing, electrical wires or cables as printable components. Instead, provide accessible tubing channels and openings. ### 4. Cutaway Design Include a removable side panel revealing the internal syringe compartment, retaining clips, linkage, control horn and hinge mechanism. Keep the wing, flaperon, linkage, hinge, pins, mounting clips and external cradle as separate printable components. ### 5. Printing and Functionality Available printer build volume: 256 × 256 × 256 mm³. Ensure every printable component fits within this envelope. Include practical assembly clearances, removable mounting features and adequate structural walls. Make the design fully parametric, particularly syringe dimensions, plunger travel, linkage length and hinge position. Prioritise reliable movement, easy assembly and visibility of the hydraulic mechanism. This is an educational school demonstration, not a flight-certified aircraft component.

Parameters

NameValueRange
Airfoil chord240 mm180 – 320
Wing span120 mm80 – 250
Maximum airfoil thickness48 mm30 – 70
Flaperon chord60 mm40 – 90
Flaperon clearance gap0.8 mm0.5 – 1.5
Flaperon deflection, positive down30 deg-25 – 35
Upper surface camber3 mm0 – 8
Internal syringe barrel diameter29 mm20 – 36
Syringe mounting clearance0.6 mm0.3 – 1.2
Syringe bay front position30 mm20 – 60
Syringe barrel bay length125 mm90 – 145
Syringe center height25 mm20 – 34
Retaining clip opening width22 mm14 – 30
Plunger channel diameter8 mm5 – 14
Syringe nozzle clearance length12 mm8 – 20
Syringe nozzle diameter4.2 mm3 – 7
Syringe finger flange diameter38 mm28 – 46
Syringe flange thickness3 mm1.5 – 5
Nominal exposed plunger length18 mm10 – 35
Required plunger travel clearance16 mm8 – 35
Plunger rod diameter6 mm3 – 10
Plunger thumb pad diameter28 mm15 – 36
Removable retaining clip wall2.4 mm1.2 – 4
Retaining clip band width6 mm4 – 10
Hinge axis height41 mm25 – 55
Hinge knuckle diameter10 mm7 – 14
Hinge pin diameter3.2 mm3 – 5
Hinge radial clearance0.3 mm0.2 – 0.5
Control horn thickness6 mm4 – 10
Linkage bolt hole diameter3.4 mm3.2 – 5.5
Linkage plate thickness4 mm3 – 7
Linkage plate width8 mm6 – 12
Linkage pivot length17 mm12 – 35
Cutaway front position24 mm15 – 70
Cutaway length151 mm100 – 175
Cutaway depth from near side53 mm25 – 58
Cutaway lower height8 mm3 – 20
Cutaway opening height35 mm20 – 45
Removable panel thickness2.4 mm1.2 – 4
Panel locating tab depth5 mm3 – 9
Panel edge overlap0.7 mm0.5 – 1
Real flexible tube diameter4.5 mm3 – 7
Underside tube exit offset22 mm12 – 35
External syringe barrel diameter21 mm16 – 28
External syringe barrel length103 mm70 – 125
External plunger access length30 mm15 – 50
External syringe nozzle offset72 mm65 – 100
External cradle clearance0.7 mm0.3 – 1.5
External cradle wall2.5 mm1.2 – 5
External cradle saddle width10 mm6 – 16
External cradle top opening16 mm10 – 24
Cradle docking tongue width14 mm8 – 24

Every value above is a live dimension. Open a model like this in the editor and each one becomes a slider you can drag before exporting.