G+1 RCC Framed Building - Cattle Shelter + 2BHK
- Bounding box
- 6417.5 × 11411 × 7380 mm
- Engine
- 3D Printing B-rep
- Parameters
- 32
- Published
- October 30, 2026
Download
Free to download and use. See the terms.
The prompt
FINAL CAD DESIGN BRIEF – G+1 RCC FRAMED BUILDING 1. Plot Dimensions and Orientation - Plot size: 22'-0" × 40'-0" - South boundary: 22'-0" - North boundary: 22'-0" - East boundary: 40'-0" - West boundary: 40'-0" - South side assumed as road-facing. - Total plot area: 880 sq.ft. Setbacks - South: 3'-0" - North: 3'-6" - East: 3'-6" - West: 1'-6" Permissible setback-based envelope - North-South dimension: 17'-0" - East-West dimension: 33'-6" - Approximate area: 569.25 sq.ft. 2. RCC Structural Requirements - G+1 RCC framed structure. - Exactly 8 columns. - Column size: 9" × 18". - Mark columns C1 to C8. - Provide coordinated column grid and beam layout. - Maintain vertical alignment across floors. - No additional columns without approval. - Structural adequacy to be verified through calculations. 3. Ground Floor – Cattle Shelter - Functional cattle standing and movement space. - Feeding trough and water trough. - Non-slip flooring. - Proper floor slope towards drainage. - Manure collection arrangement. - Natural ventilation and lighting. - Suitable entrance and cleaning access. Ground Floor RCC Slab Restriction Maintain a 6-inch horizontal gap from all four sides of the applicable main building boundary for the main RCC slab. Show this offset separately from cantilever projections. 4. First Floor – 2BHK Provide: - Living room. - Dining. - Master bedroom. - Second bedroom. - Kitchen. - Attached toilet. - Common toilet. - Utility area. - Balcony wherever feasible. Provide complete room dimensions, furniture layout, door and window schedule, ventilation and circulation. 5. North-Side Staircase - Locate staircase on North side. - Starting point at approximately the middle of North boundary. - Staircase shall progress towards North-West. - Show landing, tread, riser, headroom and direction of ascent. - Maintain safe first-floor access. 6. Cantilever Projections Provide variable cantilever projections on all four sides at both Ground Floor and First Floor levels. - South: Variable as per design. - North: Variable as per design. - East: Variable as per design. - West: Variable as per design. Show actual dimensions after architectural coordination and structural calculations. Clearly distinguish main slabs and cantilever slabs. Check local setback regulations and permissible projections. 7. Required CAD Sheets A. Ground Floor cattle shelter plan. B. Ground Floor column and beam layout. C. First Floor 2BHK architectural plan. D. First Floor structural layout. E. Four-side cantilever details. F. Building sections and four elevations. G. Column and beam schedules. H. Staircase details. 8. CAD Presentation - Feet and inches. - Editable DWG. - Printable PDF. - Proper CAD layers. - Dimension lines and grid lines. - North arrow. - Drawing scale and title block. - Separate architectural and structural drawings.
Parameters
| Name | Value | Range |
|---|---|---|
| East-West envelope 17'-0" | 5182 mm | 3000 – 6500 |
| North-South envelope 33'-6" | 10211 mm | 6000 – 12500 |
| Column width E-W 9" | 229 mm | 150 – 400 |
| Column depth N-S 18" | 457 mm | 200 – 600 |
| Interior grid line 2 | 3404 mm | 1000 – 9000 |
| Interior grid line 3 | 6807 mm | 1000 – 9000 |
| Isolated footing size | 1200 mm | 600 – 2500 |
| Footing thickness | 300 mm | 150 – 600 |
| Plinth beam width | 229 mm | 150 – 400 |
| Plinth beam depth | 450 mm | 200 – 800 |
| Beam width | 229 mm | 150 – 400 |
| Beam depth | 450 mm | 200 – 800 |
| Slab thickness | 125 mm | 80 – 250 |
| Ground slab inset from boundary 6" | 152 mm | 0 – 600 |
| Ground floor slab top | 1500 mm | 500 – 3000 |
| Floor-to-floor height | 3200 mm | 2400 – 4500 |
| South projection | 600 mm | 0 – 1500 |
| North projection | 600 mm | 0 – 1500 |
| East projection | 750 mm | 0 – 1500 |
| West projection | 450 mm | 0 – 1500 |
| Cantilever slab thickness | 175 mm | 80 – 300 |
| Stair flight width | 1000 mm | 700 – 1500 |
| Tread going | 250 mm | 200 – 320 |
| Nominal riser | 150 mm | 120 – 200 |
| Trough width | 450 mm | 300 – 900 |
| Trough length | 600 mm | 300 – 1200 |
| Trough height | 600 mm | 300 – 900 |
| Trough wall thickness | 40 mm | 25 – 80 |
| Partition thickness | 100 mm | 75 – 200 |
| Partition height | 2700 mm | 2100 – 3200 |
| Door opening width | 800 mm | 600 – 1200 |
| Door opening height | 2100 mm | 1800 – 2400 |
Every value above is a live dimension. Open a model like this in the editor and each one becomes a slider you can drag before exporting.
More models
Browse the full gallery →Cylindrical Stainless Steel Basket with Folding Handles
Design a cylindrical 304 stainless steel basket with an outer diameter of 200 mm and height of 250 mm. The basket has solid side walls with no perforations. The bottom plate contai
Immersion Cooling Enclosure
Design a sealed high-pressure dielectric immersion cooling enclosure for cylindrical battery cells. Internal cavity dimensions: 540mm length, 360mm width, 160mm height with 6mm wal
Simple BWB with Propulsion Tube
Prompt: "A simple, solid Blended Wing Body (BWB) flying wing. Dimensions: wingspan 6.5 meters, center chord 1.53 meters, root thickness 35 centimeters, tapering to 15 centimeters a
Engranaje recto 50 dientes, módulo 2
Engranaje recto de 50 dientes, diámetro exterior 104 mm, diámetro de raíz 95 mm, espesor 10 mm y ángulo de presión 20°. Crear como sólido 3D con un agujero central de 8.2 mm de diá
G+1 Party Hall Structural Shell
G+1 Party Hall – AutoCAD Design Prompt Design a G+1 RCC-framed Party Hall in AutoCAD with detailed Ground Floor Plan, First Floor Plan, and all-side elevations (front, rear, left
Rope Winch Drum
Create a fully parametric CAD model of a rope winch drum for a construction hoist. Requirements: - Output format: STEP (.step or .stp) - Units: millimeters - Solid body only (no