3D preview of TRIORA ANDROAXIS READER - Exploded Assembly
Loading the interactive model…
Interactive 3D model of TRIORA ANDROAXIS READER - Exploded Assembly

Brackets and mounts

TRIORA ANDROAXIS READER - Exploded Assembly

3 views
Bounding box
2042.8 × 100.0 × 80.0 mm
Engine
Precision B-rep
Parameters
53
Published
November 25, 2026

Download

Free to download and use. See the terms.

The prompt

Design a complete, editable, parametric 3D CAD assembly of **TRIORA ANDROAXIS READER**, a compact biomedical instrument for research-stage SHBG testing. Create a professional white-and-teal tabletop device with a front digital display, cartridge insertion slot, power button and USB-C port. Include separate, accurately positioned 3D components: - Main enclosure with upper and lower housing. - Removable SHBG lateral-flow test cartridge with test strip and optical window. - Light-controlled optical chamber containing a provisional 470 nm LED, excitation path, emission filter and photodetector. - Internal electronics placeholders: ESP32-S3, LED driver, signal-processing PCB, ADC, rechargeable battery and display module. - Cartridge guides, PCB mounts, fasteners and internal supports. Build this as a **real multi-part mechanical assembly**, not a single solid, illustration or rendered concept. Use realistic proportions, editable dimensions, meaningful component names, proper clearances and correct cartridge-to-optical-chamber alignment. Generate front, side, top, internal and exploded views. Prioritise mechanical feasibility and component fit. Export the editable native CAD project, complete assembly STEP, individual component STEP, STL and GLB files wherever supported. If any format is unavailable, clearly state it. Do not invent validated sensor performance or claim clinical accuracy. Use provisional dimensions and identify engineering assumptions. **Final goal:** An engineering-review-ready 3D prototype that can later be 3D printed, physically assembled, integrated with electronics and displayed interactively in TRIORA BioSense software through Base44.

Parameters

NameValueRange
Enclosure Width150 mm100 – 220
Enclosure Depth100 mm70 – 160
Lower Housing Height30 mm18 – 50
Upper Cover Height50 mm25 – 80
Wall Thickness2.5 mm1.5 – 5
Floor Thickness3 mm1.5 – 6
Outer Corner Fillet5 mm0 – 8
Cartridge Slot Width30 mm20 – 45
Cartridge Slot Height10.6 mm8 – 20
Cartridge Slot Centre Z20.5 mm8 – 40
USB-C Cutout Width9 mm6 – 14
USB-C Cutout Height3.4 mm2 – 6
USB-C Cutout X50 mm0 – 70
USB-C Cutout Z8 mm3 – 25
Power Button Hole Dia8 mm4 – 14
Power Button X-50 mm-70 – 0
Power Button Z8 mm3 – 25
PCB Boss Diameter7 mm4 – 12
PCB Boss Height5 mm2 – 12
Display Width70 mm40 – 110
Display Height45 mm25 – 70
Display Depth8 mm3 – 16
Display Window Width64 mm30 – 100
Display Window Height40 mm20 – 65
Cartridge Length85 mm50 – 120
Cartridge Width28 mm15 – 45
Cartridge Height9 mm5 – 16
Cartridge Y Position-22.5 mm-60 – 0
Cartridge Z Position20.5 mm8 – 40
Test Strip Length60 mm30 – 90
Test Strip Width6 mm3 – 12
Test Strip Thickness0.8 mm0.3 – 2
Chamber Width45 mm28 – 70
Chamber Depth30 mm18 – 50
Chamber Height19 mm10 – 30
Chamber Y Position-5 mm-30 – 20
Port Offset from Axis8 mm2 – 18
Optical Port Diameter5 mm2 – 10
LED Module Square Size12 mm6 – 20
Emission Filter Size10 mm5 – 20
Emission Filter Thickness1 mm0.5 – 3
Photodetector PCB Size15 mm8 – 25
Photodetector PCB Thickness1.6 mm0.8 – 3
Main PCB Length95 mm60 – 130
Main PCB Width65 mm40 – 90
Main PCB Thickness1.6 mm0.8 – 3
Battery Length60 mm30 – 90
Battery Width30 mm15 – 45
Battery Thickness8 mm4 – 16
Guide Rail Length27 mm10 – 60
Guide Rail Width4 mm2 – 8
Guide Rail Height11 mm4 – 20
Exploded Layout Gap25 mm5 – 80

Every value above is a live dimension. Open a model like this in the editor and each one becomes a slider you can drag before exporting.