3D preview of Sg90 parallelogram arm
Loading the interactive model…
Interactive 3D model of Sg90 parallelogram arm

Brackets and mounts

Sg90 parallelogram arm

1 views
Bounding box
260 × 101.0 × 100 mm
Engine
Robotics B-rep
Parameters
11
Published
November 23, 2026

Download

Free to download and use. See the terms.

The prompt

Create a fully functional, parametric and 3D-printable robotic arm assembly using EXACTLY four standard SG90 9g positional servos (180°). MECHANISMS: 1. Rotating base: horizontal rotation driven by servo 1. 2. Shoulder: first arm segment moves vertically using servo 2. 3. Elbow: second arm segment moves independently using servo 3. 4. Gripper: two opposing movable jaws operated by servo 4. CRITICAL: Use a real mechanical four-bar parallelogram linkage to keep the gripper platform horizontal relative to the ground during shoulder and elbow movements. No additional motors or servos. GRIPPER: - Two opposing, symmetrically moving jaws. - Servo-driven mechanical transmission. - Rounded contact surfaces and mechanical movement stops. HC-SR04 ULTRASONIC SENSOR MOUNT: - Include a dedicated, separate, removable 3D-printable mounting bracket for one standard HC-SR04 sensor (45 × 20 × 15 mm). - Position it beside or slightly behind the gripper, attached to its platform. - The sensor MUST face vertically downward toward the ground. - Both ultrasonic transducers must remain completely exposed and unobstructed. - Use a small rectangular support with retaining edges and attachment points for rubber bands, elastic bands or adhesive tape. - Do not require screws or permanent attachment to the sensor. - Include clearance for the four-pin connector and cables. - Make the sensor easy to remove and reinstall. - Ensure the bracket does not interfere with jaw movement, linkage movement or object gripping. - Export the bracket as its own STL file. CONSTRUCTION: - Dimension all four servo mounts for actual SG90 bodies, mounting tabs, holes and horns. - Include all joints, links, spacers, pins, adapters and fasteners. - Provide cable routing and mounting space. - Design for PLA/PETG FDM printing with appropriate moving-part clearances. - Avoid collisions and unnecessary supports. - Ensure structural stability. OUTPUT: Generate actual mechanical CAD geometry, not concept art or visual-only models. Create separate printable parts and a complete assembled model. Provide individual STL files and STEP/3MF assembly exports where supported. Include dimensions, parts list, fastener specifications, print orientations and numbered assembly instructions. Prioritize mechanical functionality and correct geometry over appearance. Verify the parallelogram geometry, servo clearances, joint movement and component collisions. Do not substitute missing mechanisms with decorative geometry.

Parameters

NameValueRange
Base height38 mm25 – 80
Shoulder pivot height42 mm30 – 90
Upper arm pivot length95 mm65 – 130
Forearm pivot length85 mm55 – 120
Parallelogram offset14 mm8 – 24
Parallelogram coupler length95 mm65 – 130
Jaw carriage spacing36 mm24 – 55
Jaw travel per side12 mm6 – 20
HC-SR04 bracket X offset0 mm-30 – 30
HC-SR04 bracket Y offset-42 mm-70 – -20
HC-SR04 bracket drop below platform12 mm5 – 30

Every value above is a live dimension. Open a model like this in the editor and each one becomes a slider you can drag before exporting.

Sg90 parallelogram arm - Free CAD Model (STEP, STL) | TextoCAD