13515.827750.01590.0
Loading the interactive model…
Interactive 3D model of Retractable Tensile Canopy Assembly

Everything else

Retractable Tensile Canopy Assembly

9 views
Bounding box
27750.0 × 13515.8 × 1590.0 mm
Engine
Precision B-rep
Parameters
27
Published
August 20, 2026

Download

Free to download and use. See the terms.

The prompt

Create a professional architectural and engineering CAD design for a large outdoor retractable tensile canopy / awning system for RED HOUSE GROUP. PROJECT TYPE: Commercial outdoor shading canopy / retractable tensile awning system installed above the windows of an existing building. OVERALL PROJECT DIMENSIONS: Overall length: 27.50 meters Overall projection/depth: 13.45 meters Total area: approximately 369.875 square meters MODULE CONFIGURATION: Divide the complete 27.50 m length into exactly 5 equal canopy modules. Each module: Width: 5.50 meters Projection/depth: 13.45 meters Therefore: 5 modules × 5.50 m = 27.50 m total length. Each module must be clearly separated structurally while creating one continuous professional canopy system. INSTALLATION: The canopy must be installed ABOVE the existing building windows, attached to the building facade / structural wall. The front edge must be supported by a suitable steel structural frame. Show the connection points between the canopy structure and the existing building. Do NOT place the main supporting structure on the ground unless structurally necessary. ROOF / FABRIC: Use a high-quality tensile PVC-coated fabric membrane suitable for outdoor architectural shading. The membrane should be professionally tensioned. Show realistic fabric tension and clean straight edges. Use a modern premium architectural appearance. DRAINAGE: The complete canopy must have a controlled slope toward the designated drainage side. Provide approximately 1.00 meter vertical level difference / slope for rainwater drainage. The slope must be clearly visible in the side elevation and 3D model. Show the direction of rainwater flow with arrows. Design the front and side edges so rain

Parameters

NameValueRange
Overall Length27500 mm1000 – 40000
Overall Projection / Depth13450 mm3000 – 20000
Front Drainage Drop1000 mm100 – 2000
Module Width5500 mm1000 – 10000
Number of Modules5 mm1 – 10
Rear Beam Length27500 mm1000 – 40000
Rear Beam Width150 mm50 – 400
Rear Beam Height200 mm50 – 500
Front Beam Length27500 mm1000 – 40000
Front Beam Width300 mm100 – 600
Front Beam Height400 mm100 – 800
Number of Rafters5 mm1 – 12
Rafter Width200 mm50 – 500
Rafter Height350 mm50 – 600
Tie Rod Diameter100 mm20 – 300
Tie Rod Length6000 mm1000 – 12000
Drive Unit Length350 mm100 – 1000
Drive Unit Width200 mm50 – 600
Drive Unit Height150 mm50 – 500
Fabric Membrane Thickness10 mm1 – 50
Gutter Length27500 mm1000 – 40000
Gutter Width120 mm50 – 400
Gutter Height150 mm50 – 400
Bracket Length250 mm100 – 1000
Bracket Thickness10 mm2 – 60
Bracket Height150 mm50 – 500
Bracket Count6 mm1 – 20

Every value above is a live dimension. Open a model like this in the editor and each one becomes a slider you can drag before exporting.