398.8304.8711.2
Loading the interactive model…
Interactive 3D model of Rear Airflow Pressure Plenum with Shelf Ledges and Recessed Blower Mount

Brackets and mounts

Rear Airflow Pressure Plenum with Shelf Ledges and Recessed Blower Mount

13 views
Bounding box
304.8 × 398.8 × 711.2 mm
Engine
Precision B-rep
Parameters
34
Published
August 9, 2026

Download

Free to download and use. See the terms.

The prompt

Generate a parametric 3D CAD model of an enclosed, flat-pack rear airflow pressure plenum with integrated shelf supports and a recessed low-profile blower mount. All components must be designed strictly for 0.25-inch thick sheet material. 1. Main Rear Duct: Generate a solid flat back wall that is 15.7 inches wide and 28.0 inches tall. 2. Side Walls: Generate two solid side walls extending forward by 12.0 inches from the extreme left and right edges of the back wall. 3. Shelf Ledges: On the interior faces of both 12.0-inch side walls, generate 7 horizontal shelf ledges. Each ledge must run the full 12.0-inch depth, protrude inward by 0.5 inches, have a vertical thickness of 0.25 inches, and be spaced at a 3.875-inch vertical pitch starting 2.0 inches from the bottom edge. 4. Front Pressure Face: Enclose the front of the rear duct by generating a flat front panel spaced exactly 1.25 inches away from the back wall. 5. Graduated Airflow Slots: Cut 7 horizontal airflow slots into this front panel. Center them horizontally and make them 14.0 inches wide. Position the bottom edge of each slot perfectly flush with the top surface of its corresponding shelf ledge. Set the vertical heights of the slots progressively from bottom to top: Tier 1 (bottom) is 0.13 inches, Tier 2 is 0.14 inches, Tier 3 is 0.16 inches, Tier 4 is 0.17 inches, Tier 5 is 0.18 inches, Tier 6 is 0.20 inches, and Tier 7 (top) is 0.21 inches. 6. Recessed Blower Pocket & Intake: At the bottom center of the front panel (below Tier 1), generate a 2.25-inch wide by 0.75-inch tall rectangular exhaust cutout flush with an internal mounting pocket designed to recess a thin 15mm-20mm centrifugal blower directly inside the plenum channel. 7. Assembly Joinery: Apply 0.25-inch mortise-and-tenon (tab-and-slot) interlocking joints along all mating panel edges for flat-pack assembly.

Parameters

NameValueRange
Back Wall Width398.8 mm300 – 600
Back Wall Height711.2 mm500 – 1000
Back Wall Thickness6.35 mm3 – 10
Side Wall Depth304.8 mm200 – 500
Side Wall Height711.2 mm500 – 1000
Side Wall Thickness6.35 mm3 – 10
Front Panel Width386.1 mm300 – 500
Front Panel Height711.2 mm500 – 1000
Front Panel Thickness6.35 mm3 – 10
Front Panel X Offset (back face from back wall)31.75 mm20 – 100
Airflow Slot Width355.6 mm200 – 400
Slot Height Tier 1 (bottom)3.3 mm1 – 10
Slot Height Tier 23.56 mm1 – 10
Slot Height Tier 34.06 mm1 – 10
Slot Height Tier 44.32 mm1 – 10
Slot Height Tier 54.57 mm1 – 10
Slot Height Tier 65.08 mm1 – 10
Slot Height Tier 7 (top)5.33 mm1 – 10
Shelf Ledge Depth (front‑to‑back)304.8 mm200 – 500
Shelf Ledge Projection (inward)12.7 mm5 – 30
Shelf Ledge Thickness6.35 mm3 – 10
Shelf Ledge Vertical Pitch98.43 mm50 – 200
Shelf Ledge Bottom Offset (from floor)50.8 mm10 – 200
Blower Exhaust Cutout Width57.15 mm20 – 150
Blower Exhaust Cutout Height19.05 mm5 – 50
Blower Cutout Center Z35 mm20 – 200
Blower Pocket Inner Width75 mm40 – 120
Blower Pocket Inner Height20 mm10 – 40
Blower Pocket Inner Depth20 mm10 – 40
Blower Pocket Wall Thickness6.35 mm3 – 10
Tenon Length6.35 mm3 – 15
Tenon Width20 mm10 – 50
Number of Mortises per Edge41 – 10
Mortise Margin from Top/Bottom25.4 mm10 – 100

Every value above is a live dimension. Open a model like this in the editor and each one becomes a slider you can drag before exporting.