Interactive 3D model of Prototype 2B Six-Source Dispenser (Assembled)

Brackets and mounts

Prototype 2B Six-Source Dispenser (Assembled)

16 views
Bounding box
360.0 × 302.0 × 160.0 mm
Engine
Precision B-rep
Parameters
46
Published
August 9, 2026

Download

Free to download and use. See the terms.

The prompt

ASSEMBLE THE EXISTING PARTS INTO ONE COMPLETE MACHINE. Do not generate a new architecture and do not leave any components floating or separated. Preserve the existing components and arrange them on the existing rectangular base as one compact benchtop assembly. Required physical layout: Place all 6 fixed 15 mL pods vertically in a rear semicircle, evenly spaced and mounted in holders attached to the base. Place the 6-port rotary selector valve in the centre, in front of the pods. Connect each pod to one selector inlet using a short separate tube. There must be exactly 6 pod-to-selector tubes. Mount Stepper Motor 1 directly beside/under the rotary selector so it rotates the selector rotor. Place the single syringe pump horizontally on the right side of the selector. Connect the selector common outlet to the syringe using one very short shared tube. The syringe barrel must remain fixed in its holder. Mount Stepper Motor 2 inline with the syringe lead screw. Stepper Motor 2 rotates the lead screw; the lead screw moves a guided carriage that grips the syringe plunger. Include two guide rods beside the lead screw so the carriage cannot rotate. The carriage must be able to move backward to aspirate and forward to dispense. Connect the syringe outlet using one short tube to one fixed downward dispensing nozzle. Place the receiving bottle directly beneath that nozzle. Mount the receiving bottle on a load-cell weighing platform. Put the electronics enclosure at the rear-right corner, separated from all liquid paths. Exact fluid path must be visually obvious: 6 pods → 6 short independent tubes → 6-port rotary selector → ONE syringe pump → ONE short outlet tube → fixed nozzle → receiving bottle on load cell Mechanical requirements: Every component must be physically mounted to the base or a rigid bracket. No floating components. No exploded-view spacing. No disconnected parts. No tubes ending in mid-air. Keep tubing short and neatly routed. Add realistic brackets, holders, screws and supports where necessary. Keep access to the pods so they can be removed vertically. Keep the syringe removable for servicing. Keep the selector and syringe accessible. Critical architecture: There are exactly 2 stepper motors total: Stepper 1 → rotary selector Stepper 2 → lead screw → syringe plunger There is exactly 1 syringe pump. Do NOT create six syringe pumps, six peristaltic pumps, a rotating nozzle wheel, or a moving bottle. The output should look like a fully assembled functional prototype, not an exploded diagram or collection of parts.

Parameters

NameValueRange
Base Width360 mm200 – 600
Base Depth280 mm150 – 400
Base Thickness12 mm6 – 30
Pod Holder Width80 mm40 – 120
Pod Holder Depth15 mm5 – 30
Pod Holder Thickness15 mm5 – 30
Pocket Diameter18 mm10 – 30
Pocket Circle Radius45 mm30 – 80
Pod Body Diameter16 mm10 – 25
Pod Body Height50 mm20 – 80
Pod Nipple Length10 mm5 – 20
Pod Nipple Diameter4 mm2 – 6
Tube Outer Diameter5 mm3 – 8
Selector Housing Width60 mm30 – 100
Selector Housing Height30 mm15 – 60
Selector Housing Depth40 mm20 – 80
Selector Rotor Diameter20 mm10 – 40
Selector Port Diameter4 mm2 – 8
Selector Stepper Size42 mm20 – 60
Selector Stepper Height40 mm20 – 60
Syringe Barrel Diameter15 mm8 – 25
Syringe Barrel Length80 mm40 – 150
Guide Rod Diameter8 mm4 – 15
Lead Screw Diameter8 mm4 – 15
Carriage Width40 mm20 – 80
Carriage Depth30 mm15 – 50
Carriage Height20 mm10 – 40
Syringe Stepper Size42 mm20 – 60
Syringe Stepper Height40 mm20 – 60
Manifold Width20 mm10 – 40
Manifold Depth15 mm10 – 25
Manifold Height10 mm5 – 20
Nozzle Length25 mm10 – 50
Nozzle Diameter3 mm1 – 6
Connecting Tube OD5 mm3 – 8
Load Cell Length40 mm20 – 60
Load Cell Width30 mm15 – 50
Load Cell Thickness10 mm5 – 20
Bottle Diameter30 mm15 – 60
Bottle Height40 mm20 – 80
Flush Port Width20 mm10 – 30
Flush Port Depth15 mm10 – 25
Flush Port Height10 mm5 – 20
Enclosure Width100 mm60 – 200
Enclosure Depth80 mm50 – 150
Enclosure Height50 mm30 – 80

Every value above is a live dimension. Open a model like this in the editor and each one becomes a slider you can drag before exporting.