3D preview of Perfusable Dual-Compartment Organ-on-Chip
Loading the interactive model…
Interactive 3D model of Perfusable Dual-Compartment Organ-on-Chip

Everything else

Perfusable Dual-Compartment Organ-on-Chip

1 views
Bounding box
50.0 × 30.0 × 5.5 mm
Engine
Precision B-rep
Parameters
25
Published
November 17, 2026

Download

Free to download and use. See the terms.

The prompt

Create a dimensionally accurate, parametric CAD model of a microfluidic device based on my description. Model the device substrate, inlet and outlet ports, internal channels, and chambers as actual geometry, not just a rendered image. First generate a top-down engineering layout showing all dimensions, then generate a 3D model with the channels cut into the substrate. Make the channel widths, depths, chamber dimensions, and port locations adjustable. Export SVG/DXF for the 2D layout and STEP/STL for the 3D design wherever supported. Clearly identify any dimensions you have assumed, and verify that all intended channels connect correctly. For the cell line information i give just label each chamber with what cell line it holds. The device should have a top and bottom compartment that is seperated by a perfusable membrane. In the bottom there should be one chamber which holds a reporter cell line and has ports for a fluorescent light source and a sensor. this chamber should be conencted to the other chamber which holds parathyroid organoids. with the order being inlet parathyroid organoids chamber, reporter cell line chamber, outlet, and ahve both chambers be round. then the top area should ahve an inlet then have a chamber above the parathyroid organoids just seperated by the semi permiable membrane and then it flow to outlet. ask any questions needed before starting

Parameters

NameValueRange
Chip Length50 mm20 – 120
Chip Width30 mm15 – 100
Chamber Centreline Y15 mm4 – 50
Substrate Corner Radius2 mm0 – 6
Bottom Slab Thickness3 mm1.5 – 8
Organoid Chamber Dia8 mm2 – 20
Organoid Chamber Depth2 mm0.3 – 5
Organoid Chamber X15 mm5 – 60
Reporter Chamber Dia6 mm2 – 20
Reporter Chamber Depth2 mm0.3 – 5
Reporter Chamber X36 mm10 – 100
Connecting Channel Width0.5 mm0.1 – 3
Connecting Channel Depth0.3 mm0.1 – 2
Bottom Inlet Port Dia1.5 mm0.3 – 4
Bottom Outlet Port Dia1.5 mm0.3 – 4
Light/Sensor Port Dia1 mm0.2 – 3
Membrane Diameter10 mm3 – 30
Membrane Thickness0.05 mm0.02 – 1
Top Slab Thickness2.5 mm1 – 8
Top Chamber Dia8 mm2 – 20
Top Chamber Depth1.5 mm0.2 – 5
Top Channel Width0.5 mm0.1 – 3
Top Channel Depth0.3 mm0.1 – 2
Top Port Dia1.5 mm0.3 – 2
Top Port Bore Length5 mm1 – 20

Every value above is a live dimension. Open a model like this in the editor and each one becomes a slider you can drag before exporting.

Perfusable Dual-Compartment Organ-on-Chip - Free CAD Model (STEP, STL) | TextoCAD