3D preview of Passive Roof Vent Assembly
Loading the interactive model…
Interactive 3D model of Passive Roof Vent Assembly

Everything else

Passive Roof Vent Assembly

1 views
Bounding box
1400 × 1000 × 144.3 mm
Engine
3D Printing B-rep
Parameters
21
Published
November 25, 2026

Download

Free to download and use. See the terms.

The prompt

e Problem of "Heat Accumulation in a Vehicle Cabin While Parked" (Especially in Electric Vehicles) • The Problem: When a vehicle is parked under the sun, the cabin temperature rises significantly. This leads to increased battery energy consumption for subsequent cooling and causes damage to interior materials like leather and electronic components. • Existing Solutions: Sunshades, reflective window films, and basic solar-powered ventilation. These are either ineffective or consume energy. • Proposed Solution (Patentable): An integrated passive ventilation system built into the vehicle's roof structure that operates without electrical power. It utilizes air intake and exhaust vents based on the "stack effect" (thermal chimney principle), featuring a bimetallic thermal valve that opens and closes automatically according to temperature. Internal air channels, embedded within the roof lining, direct hot air upward and out. • Novelty: The combination of a bimetallic thermal valve (requiring no electricity) with a specifically designed internal air-channel network within the roof lining, creating a self-contained, autonomous system. This constitutes a specific structural configuration, rather than merely a generic "ventilation" method.

Parameters

NameValueRange
Roof length front-to-back1400 mm800 – 2000
Roof width1000 mm600 – 1400
Outer roof skin thickness30 mm12 – 50
Roof lining thickness25 mm10 – 45
Roof crown radius4000 mm3000 – 12000
Number of lining air channels9 mm3 – 19
Channel width20 mm8 – 40
Channel depth12 mm4 – 20
Channel length front-to-back1160 mm400 – 1600
Grille depth front-to-back120 mm60 – 300
Grille width300 mm100 – 500
Grille thickness25 mm8 – 40
Number of louver slats9 mm3 – 15
Chimney length180 mm80 – 360
Chimney width120 mm60 – 240
Chimney height60 mm20 – 200
Chimney wall thickness4 mm2 – 10
Valve flap length140 mm60 – 200
Valve flap width80 mm40 – 120
Valve flap thickness8 mm2 – 16
Opening angle when hot22 deg0 – 45

Every value above is a live dimension. Open a model like this in the editor and each one becomes a slider you can drag before exporting.

Passive Roof Vent Assembly - Free CAD Model (STEP, STL) | TextoCAD