3D preview of PanCRISP 5-Column Diagnostic Cartridge
Loading the interactive model…
Interactive 3D model of PanCRISP 5-Column Diagnostic Cartridge

Everything else

PanCRISP 5-Column Diagnostic Cartridge

1 views
Bounding box
52.0 × 12.0 × 60.0 mm
Engine
Precision B-rep
Parameters
16
Published
September 27, 2026

Download

Free to download and use. See the terms.

The prompt

The main intention behind the design of the PanCrisp cartridge is to combine several different parts of sample processing into one unit. It is composed of five vertical columns arranged side by side in a single cartridge. Each column has a designated area for a particular component of the diagnostic process. The upper end of the columns provides a place to introduce a sample or reagents into the system, whereas the lower ends include the processing and detection areas. Such an arrangement reduces the need for transferring samples between separate tubes and prevents contamination during the diagnostic process. The first stage of the diagnostic process starts with introducing saliva into the designated area of the cartridge where samples should be located. Lysis buffer is used in the system to facilitate exosomes' destruction and the release of miRNA. The sample moves through the filtration region of the cartridge after lysis. The purpose of the filter is to hold unnecessary material and let desired molecular components pass through it. Additionally, the sample-processing area of the cartridge can include DNase that will reduce unnecessary DNA before the downstream detection reaction. After sample processing, the RNA is sent to the detection area containing the CRISPR-Cas13 reaction. Our PanCRISP system is capable of detecting multiple target miRNAs (miRNA-21-5p, miRNA-23a, miRNA-23b, miRNA-29c, miRNA-216). If the target sequence is present in the sample, the CRISPR-Cas13 complex is activated and cuts fluorescent reporter molecules. As a result, the fluorescence signal is produced which can be detected at the lower end of the cartridge. PanCRISP cartridge design does not require any additional manual transfer of the processed sample into another reaction tube.

Parameters

NameValueRange
Number of Columns5 count1 – 10
Cartridge Height60 mm30 – 150
Cartridge Thickness (Y)12 mm6 – 30
Column Pitch9 mm5 – 25
Edge Margin8 mm3 – 25
Column Bore Dia3 mm1 – 8
Inlet Reservoir Dia6.5 mm2 – 16
Inlet Reservoir Depth6 mm1 – 25
Bottom Seal Wall2.5 mm1 – 15
Filter Pocket Dia8 mm3 – 20
Filter Pocket Depth5 mm2 – 25
Filter Pocket From Top22 mm8 – 120
Detection Chamber Dia7 mm3 – 20
Detection Chamber Depth9 mm2 – 25
Detection Center Height7.5 mm3 – 60
Body Corner Fillet2 mm0 – 5

Every value above is a live dimension. Open a model like this in the editor and each one becomes a slider you can drag before exporting.