3D preview of Neural Organ-on-Chip with Integrated MEA and Y-Junction Gradient Generator
Loading the interactive model…
Interactive 3D model of Neural Organ-on-Chip with Integrated MEA and Y-Junction Gradient Generator

Everything else

Neural Organ-on-Chip with Integrated MEA and Y-Junction Gradient Generator

1 views
Bounding box
64.0 × 44.0 × 5.0 mm
Engine
Precision B-rep
Parameters
26
Published
October 8, 2026

Download

Free to download and use. See the terms.

The prompt

Refine the EXISTING model shown in the reference image. Do not rebuild or remove the existing Y-junction, two inlet ports, main channel, central culture chamber, or outlet. Complete the neural organ-on-chip architecture by adding: 1. A clearly visible MEA electrode array underneath the central neural culture chamber, centered within the existing substrate. 2. Inside the central culture chamber, create two adjacent neural culture compartments separated by a narrow barrier containing multiple parallel microtunnels. 3. The microtunnels must be narrow, parallel, symmetric, and clearly smaller than the main fluidic channels. 4. Keep the existing two-inlet Y-junction gradient generator and single outlet unchanged. 5. Keep the PDMS microfluidic layer above the rigid glass/silicon MEA substrate. 6. Ensure the MEA electrodes are positioned directly beneath the neural culture region. Use millimeters and reasonable editable dimensions where unspecified. Do not add decorative geometry, pumps, tubing, cells, or electronics. Keep the model parametric and editable. Preserve the existing successful geometry. Only add the missing MEA electrode array, neural compartments, and microtunnels.

Parameters

NameValueRange
Substrate Length64 mm40 – 120
Substrate Width44 mm25 – 100
Substrate Thickness1 mm0.3 – 3
Electrode Count (per half-axis)3 pcs1 – 8
Electrode Pitch0.8 mm0.2 – 5
Electrode Site Diameter0.3 mm0.1 – 2
Innermost Electrode Offset0.4 mm0.1 – 5
Electrode Site Height0.2 mm0.05 – 1
PDMS Layer Length60 mm30 – 120
PDMS Layer Width40 mm20 – 100
PDMS Layer Thickness4 mm1 – 10
Outer Corner Fillet1.5 mm0 – 5
Microfluidic Channel Width0.6 mm0.2 – 3
Channel Depth (from top face)4 mm0.2 – 8
Inlet / Outlet Port Diameter1 mm0.4 – 4
Port Distance From Chip Centre22 mm5 – 30
Inlet Port Half-Spacing (Y)8 mm1 – 18
Y-Junction Position (X)-10 mm-25 – -2
Culture Chamber Length12 mm4 – 30
Culture Chamber Width6 mm2 – 20
Culture Chamber Depth4 mm0.5 – 8
Compartment Barrier Thickness0.2 mm0.1 – 2
Microtunnel Width0.15 mm0.05 – 1
Microtunnel Count9 pcs1 – 30
Microtunnel Pitch0.5 mm0.1 – 3
Microtunnel Depth (from top face)4 mm0.2 – 8

Every value above is a live dimension. Open a model like this in the editor and each one becomes a slider you can drag before exporting.

Neural Organ-on-Chip with Integrated MEA and Y-Junction Gradient Generator - Free CAD Model (STEP, STL) | TextoCAD