3D preview of Container Data Center Layout
Loading the interactive model…
Interactive 3D model of Container Data Center Layout

Organic and sculpted

Container Data Center Layout

1 views
Bounding box
120 × 65.7 × 47.2 mm
Engine
Organic B-rep
Parameters
0
Published
November 5, 2026

Download

Free to download and use. See the terms.

The prompt

Generate an architectural and space planning layout in AutoCAD DWG format for a modern container solution data center consisting of 3 distinct rooms. The drawing must use architectural standards, clear layering, precise line types, and metric dimensions (millimeters). ### 1. GENERAL LAYOUT & WALL STRUCTURE - Total Footprint: 15 meters wide. - Exterior walls: 150mm thick (Layer: A-WALL-EXTR). - Interior partition walls: 100mm thick, slab-to-slab fire-rated partitions (Layer: A-WALL-INTR). ### 2. ROOM BREAKDOWN & REQUIREMENTS ROOM 1: THE SERVER ROOM (White Space) - Dimensions: 15m wide x deept need to manage with cabinet & uniluty distribution. - Layout: 2 or 3 parallel rows of server racks. Total 15 (7 racks 600mm wide x 300mm, 7 racks 900mm wide deep per rack x 300mm deep per rack & 7 racks 600mm wide x 800mm deep per rack). - Aisle Design: Alternate between Hot Aisles (1200mm wide) and Cold Aisles (1200mm wide) using a Hot/Cold Aisle Containment strategy. Indicate containment doors at row ends. - Cooling: Place 2 In-Row InRow CRAC/CRAH units (600mm wide x 800mm deep) interspersed within the rack rows. - Access: 2 Single doors (1200mm total width) opening outward on both wide side. ROOM 2: THE GENERATOR ROOM - Dimensions: 5m wide x deepT align with server room. - Layout: generator in middle of the Room (4000mm wide x 1500mm deep). - Cable Trays: Draw an overhead ladder rack/cable tray system (450mm wide) running above the rack rows and exiting toward Room 1. * 2 Modular UPS systems (1200mm wide x 1000mm deep). * 2 Battery racks (1500mm wide x 800mm deep) positioned against the back wall with 1000mm clear clearance in front. * 2 Main Power Distribution Board (800mm wide x 150mm deep) along the side wall. * 1 ATS Panel with Cable Drum (800mm wide x 600mm deep) along the side wall. - Access: Single heavy-duty secure door (1200mm wide) opening outward. ROOM 3: CRAC UNITS OUTDOOR UNITS - Dimensions: 6m wide x 12m deep. - Equipment Layout: * 2 CRACK Units (800mm wide x 400mm deep). * need enough ventilation grill to pass the hot air out & to get fresh air for CRAC outdoor units. - Access: Single heavy-duty secure door (1200mm wide) opening outward. ### 3. LAYER & DRAFTING STANDARDS - Organize elements using standard AIA layering: E-POWR-EQPM (Electrical equipment), T-COMM-EQPM (Telecom/Racks), M-HVAC-EQPM (Cooling units), A-DOOR (Doors), and A-ANNO-TEXT (Labels/Dimensions). - Include standard blocks for: Racks, UPS modules, CRAC units, and electrical panels. - Add clear dimensions for maintenance clearance zones (minimum 1000mm clearance in front and back of all electrical panels and server rows).

Parameters

This model was generated without adjustable parameters. Open it in the editor to add your own dimensions.

Every value above is a live dimension. Open a model like this in the editor and each one becomes a slider you can drag before exporting.

Container Data Center Layout - Free CAD Model (STEP, STL) | TextoCAD