15500.023300.06550.0
Loading the interactive model…
Interactive 3D model of Classroom Block - Assembled Building Model

Plates and panels

Classroom Block - Assembled Building Model

1 views
Bounding box
23300.0 × 15500.0 × 6550.0 mm
Engine
Precision B-rep
Parameters
32
Published
October 11, 2026

Download

Free to download and use. See the terms.

The prompt

Presentation Drawing Requirements of the PAT: 1. Freehand Design Drawings: • Floor plan/s and a 3D drawing for each of the 3 concept designs of the Classroom Block. The 3D drawing can be of a specific design aspect of the Classroom Block and should include rendering, texture and colour. 2. A set of Working Drawings of the Classroom Block, drawn to scale showing: (2D or 3D CAD drawing can be used) • Floor plans clearly showing the following: ▪ The position of all windows and doors ▪ Room designations and floor finishes ▪ Set-out dimensions and the cutting plane ▪ Fixtures and fixture codes ▪ Electrical components and wiring ▪ Scale(s), labels and notes ▪ All hatching detail (colour can be used in accordance with standard drawing practice) ▪ Plumbing fixtures and North Point ▪ Handicap friendly features ▪ Rainwater capture tanks • Elevations clearly showing the following: ▪ The four elevations of the new Classroom Block ▪ Height dimensions and labels (FFL and NGL) ▪ Window and door openings ▪ Roof and wall detail ▪ Solar panels for the solar water geyser • A detailed Sectional Elevation showing the following: ▪ The section from the foundation to the roof ▪ Either a sectional door or sectional window or both ▪ Labels (FFL, NGL, DPC, drawing title) • Notes, Title Block and Border 3. A complete detailed Site Plan (2D CAD drawing), drawn to scale, showing the following: • The position and layout of the new Classroom Block in relation to the existing school • All sewerage and drainage for the new Classroom Block, which connects to the new septic tank or grey water system • The site plan may contain artistic features, or it may be rendered • Notes and North Point 4. A Perspective Drawing (Instrument drawing or 2D CAD. No 3D generated image may be used) of the new Classroom Block, showing the following: • The correct perspective layout • The vanishing points, clearly labelled • The perspective details according to the plan NATIONAL SENIOR CERTIFICATE: ENGINEERING GRAPHICS AND DESIGN (PAT) Page 4 of 17 IEB © Copyright 2023 PLEASE TURN OVER 5. All the drawings must be presented on A3 drawing sheets, correctly set up with civil borders, name and title blocks. Drawing Methods: The PAT must provide clear evidence that a high level of competency has been attained by the learners in all the required drawing methods, namely: • Freehand drawing (This should include all the preliminary sketch drawings and diagrams produced during the design process) • Instrument drawing (2-point perspective drawing) (2D CAD may be used) • Computer-Aided Design system. (All the working drawings, apart from the perspective drawing if the learner chooses to use instruments, must be done on a CAD program. 2D and 3D CAD drawing programs may be used)

Parameters

NameValueRange
Foundation Length20000 mm5000 – 40000
Foundation Width12000 mm4000 – 30000
Foundation Depth600 mm200 – 1500
Floor Slab Thickness150 mm50 – 400
Wall Thickness230 mm100 – 500
Wall Height3000 mm2200 – 6000
Roof Length21000 mm6000 – 45000
Roof Width13000 mm5000 – 35000
Roof Ridge Height1500 mm300 – 5000
Window Width1500 mm300 – 4000
Window Height1200 mm300 – 3000
Window Sill Above FFL900 mm0 – 2000
Windows per Long Wall4 off0 – 12
Door Width900 mm600 – 2000
Door Height2100 mm1500 – 3000
Rainwater Tank Diameter1500 mm500 – 4000
Rainwater Tank Height1800 mm500 – 4000
Solar Panel Length2000 mm500 – 4000
Solar Panel Width1000 mm300 – 2500
Solar Panel Thickness50 mm10 – 200
Distribution Board Width400 mm100 – 1200
Distribution Board Height600 mm200 – 1800
Distribution Board Depth100 mm20 – 400
Sanitary Fixture Width600 mm200 – 1500
Sanitary Fixture Depth500 mm200 – 1200
Sanitary Fixture Height750 mm200 – 1500
Septic Tank Length3000 mm1000 – 8000
Septic Tank Width2000 mm800 – 6000
Septic Tank Depth2000 mm800 – 4000
Accessible Ramp Width1200 mm900 – 3000
Accessible Ramp Length3000 mm800 – 8000
Accessible Ramp Rise150 mm50 – 1000

Every value above is a live dimension. Open a model like this in the editor and each one becomes a slider you can drag before exporting.