286.01225.0150.0
Loading the interactive model…
Interactive 3D model of Six-Source Precision Liquid Dispenser Assembly

Brackets and mounts

Six-Source Precision Liquid Dispenser Assembly

30 views
Bounding box
1225.0 × 286.0 × 150.0 mm
Engine
Precision B-rep
Parameters
47
Published
August 9, 2026

Download

Free to download and use. See the terms.

The prompt

Create a parametric CAD assembly for Prototype 2B, a six-source precision liquid dispenser. Core architecture: 6 fixed removable 15 mL liquid pods arranged in a semicircle each pod has one short dedicated 3 mm ID × 5 mm OD tube all 6 tubes connect to one central 6-port rotary selector valve selector valve is driven by Stepper Motor 1 (NEMA 17) selector chooses only one pod at a time selector common outlet connects to ONE precision syringe pump syringe pump uses a fixed 5 mL syringe syringe barrel stays fixed syringe plunger is moved by a carriage on two guide rods Stepper Motor 2 (NEMA 17) rotates a T8 lead screw that moves the carriage forward/backward retracting plunger aspirates liquid; advancing plunger dispenses liquid syringe output uses one short tube to one fixed downward nozzle nozzle dispenses into one fixed 15 mL receiving bottle receiving bottle sits on a 1 kg load-cell platform include an ESP32 electronics enclosure, 2 stepper drivers, HX711, power distribution, and 12V-to-5V converter Base approximately 360 × 280 × 12 mm. Pods should look like user-friendly rigid cartridges, but leave room internally for a future collapsible liquid pouch. Keep tubing very short. No long loops. Add a Hall-sensor/home-magnet provision for the rotary selector and limit-switch provisions for the syringe carriage. Add a simple service flush port on the shared selector/syringe path. Create all major parts separately and editable: pods, holders, six tubes, selector housing/rotor/shaft, selector stepper, syringe/barrel/plunger/carriage, lead screw, guide rods, syringe stepper, nozzle, bottle platform, load cell, electronics enclosure. Critical: there are only 2 stepper motors total and only 1 syringe pump. Do NOT create: six syringe pumps six peristaltic pumps rotating nozzle turret moving bottle exposed medical bags flow sensors touchscreen complicated cleaning system Fluid path must clearly be: 6 pods → 6-port selector → 1 syringe pump → 1 nozzle → receiving bottle on load cell. Prioritize mechanical realism, short fluid paths, accurate syringe motion, serviceability, and 3D-printable prototype parts.

Parameters

NameValueRange
Layout Gap100 mm30 – 200
Base Width360 mm200 – 500
Base Depth280 mm150 – 400
Base Thickness12 mm6 – 30
Holder Width220 mm150 – 300
Holder Depth160 mm100 – 200
Holder Thickness15 mm10 – 25
Pocket Diameter30.5 mm20 – 50
Pocket Circle Radius75 mm50 – 100
Pod Body Diameter30 mm15 – 40
Pod Body Height75 mm40 – 100
Outlet Nipple Length15 mm5 – 25
Outlet Nipple Diameter5 mm3 – 8
Tube Outer Diameter5 mm3 – 10
Selector Housing Width50 mm30 – 80
Selector Housing Depth40 mm30 – 80
Selector Housing Height35 mm20 – 60
Port Diameter4 mm2 – 8
Rotor Diameter10 mm6 – 20
Selector Stepper Size42 mm30 – 60
Selector Stepper Height40 mm30 – 60
Syringe Barrel Diameter15 mm8 – 30
Syringe Barrel Length85 mm40 – 150
Guide Rod Diameter8 mm4 – 12
Lead Screw Diameter8 mm4 – 12
Carriage Width30 mm15 – 50
Carriage Depth30 mm15 – 50
Carriage Height20 mm10 – 40
Syringe Stepper Size42 mm30 – 60
Syringe Stepper Height40 mm30 – 60
Manifold Width25 mm10 – 40
Manifold Depth20 mm10 – 40
Manifold Height15 mm8 – 30
Nozzle Length33 mm15 – 80
Nozzle Outer Diameter6 mm3 – 12
Connecting Tube OD5 mm3 – 8
Load Cell Length80 mm50 – 120
Load Cell Width20 mm10 – 30
Load Cell Thickness10 mm5 – 15
Bottle Diameter25 mm10 – 40
Bottle Height45 mm20 – 80
Flush Port Width20 mm10 – 30
Flush Port Depth15 mm8 – 25
Flush Port Height15 mm8 – 25
Enclosure Width120 mm80 – 200
Enclosure Depth80 mm50 – 120
Enclosure Height50 mm30 – 80

Every value above is a live dimension. Open a model like this in the editor and each one becomes a slider you can drag before exporting.